Rebar Tie Wire
LINC Systems stocks rebar tie wire for tool and hand tying: MAX TW1061T, TW898 and TW1525 tie wire coils for MAX rebar tying tools, and Grip-Rite 16 gauge tie wire rolls, in black, electro galvanized, poly coated and stainless steel. Crews use this rebar wire to tie rebar where the bars cross and secure rebar in place until the concrete is poured.
Find the Right Rebar Tie Wire
Start with how you tie: by tool or by hand. Then pick the finish for the rebar and the job. Tool wire must match your tool model, so check the tool's label or manual first.
- MAX TW1061T: gauge: 19 gauge; pack: 30 coils/box; used with: MAX TwinTier RB441T, RB443T, RB611T and RB613T; finishes at linc: Black, electro galvanized, poly coated, US-made (TW1061TUSA).
- MAX TW898: gauge: 21 gauge; pack: 50 coils/box; used with: MAX RB218, RB398/RB398S and RB518 (TW898-EG not recommended for the RB518); finishes at linc: Black, electro galvanized, poly coated, stainless steel.
- MAX TW1525: gauge: 16 gauge; pack: 50 coils/box; used with: MAX RB650, RB650A and RB655; finishes at linc: Black.
- Grip-Rite TW16312I: gauge: 16 gauge; pack: 20 rolls/box; used with: Hand tying with pliers or a tie wire reel; finishes at linc: Black.
- Grip-Rite TWPV16123I: gauge: 16.5 gauge; pack: 20 rolls/box; used with: Hand tying coated rebar; finishes at linc: PVC coated.
Not sure which tie wire fits your rebar tier? Call 800.513.9918 with the tool model and we will match it for you.
What Is Rebar Tie Wire?
Rebar tie wire, also called tie wire or bar tie wire, is soft, annealed steel wire used to tie reinforcing steel for concrete construction (rebar) together where the bars cross. These rebar ties hold the rebar mat or cage in place, usually sitting on rebar chairs, while crews walk on it and while the concrete is placed and vibrated. Once the concrete cures, the concrete and rebar carry the load. The tie wire's job is to keep the steel where the drawings put it until then. That is why rebar needs to be tied: loose bars shift when crews walk the mat and when concrete is placed.
Tie wire is annealed (heat treated) so it bends and twists easily without snapping. It is sold two ways: in small coils (spools) for battery-powered rebar tying tools, and in rebar tie wire rolls for tying by hand. For other jobsite tools, browse our tools and accessories. Rebar tie wire is used in foundations, slabs, walls, columns, precast work and infrastructure such as bridges and roads.
Tie Wire Coils for Rebar Tying Tools
A rebar tying tool (rebar tier, or rebar tie gun) is an automatic rebar tying tool: it wraps wire around the crossed bars, twists it and cuts it in about a second. Each tool takes one specific wire, so the coil must match the tool model. Rebar tiers make the same rebar ties every time, which speeds up big slabs and decks.
MAX TW1061T Tie Wire (19ga)
TW1061T is a 19 gauge wire made for TwinTier rebar tying: the MAX TwinTier RB441T, RB443T, RB611T and RB613T, which feed two wires at once for fast, strong ties. LINC stocks it in black, electro galvanized and poly coated, plus a US-made version (TW1061TUSA), 30 coils to a box. The electro galvanized version is TW1061T-EG, and the poly coated version is TW1061-PC.
MAX TW898 Rebar Tie Wire
MAX TW898 rebar tie wire is a 21 gauge wire for the MAX RB218, RB398/RB398S and RB518. LINC stocks it in black, electro galvanized, poly coated and stainless steel, 50 coils to a box. The electro galvanized version, TW898-EG, is not recommended for the RB518.
MAX TW1525 Tie Wire
TW1525 is a 16 gauge wire for the MAX RB650, RB650A and RB655. LINC stocks it 50 coils to a box.
Shop our rebar tying tools to pair the right tool with the right wire.
16 Gauge Rebar Tie Wire Rolls for Hand Tying
For hand tying, crews use 16 gauge rebar tie wire on a roll, reel or wire spool and twist each wire tie with tie wire pliers or a tie wire twister. Hand tying rolls are made of 16 gauge black soft annealed wire, or coated wire, and 16 gauge is the standard for hand tying because it is strong enough to hold the bars and soft enough to twist quickly. LINC stocks Grip-Rite rebar tie wire 16 gauge (16 ga) rolls and 16.5 gauge PVC coated rolls, 20 rolls to a box. Each rebar tie wire roll is black annealed steel tie wire (16 gauge black), or PVC coated wire for coated rebar.
Common Hand Rebar Ties
The snap tie (single wrap) is the fastest of the rebar ties and is used on flat mats where the bars won't be pushed around much. The saddle tie and wrap-and-saddle tie hold better and are used on walls, columns and anywhere the steel will be climbed on or bumped during the pour. The figure-eight tie holds bars against twisting. The job's drawings or the engineer may call for a specific tie in some areas.
Rebar Tie Wire Finishes: Black Annealed, Electro Galvanized, Coated and Stainless Steel Wire
Match the tie wire finish to the rebar and the conditions. The finish doesn't change how rebar ties are made, only where they can be used.
Black Annealed Tie Wire
Plain black annealed steel rebar tie wire is the standard for uncoated (black) rebar. It costs the least and is fully covered by concrete once the pour is done.
Electro Galvanized Tie Wire
Zinc-plated tie wire resists surface rust while the steel sits exposed before the pour, and is often used with galvanized rebar.
Poly Coated and PVC Coated Tie Wire
Coated tie wire is used with epoxy-coated rebar so the tie does not scratch the bar's coating. Specs for coated rebar often require coated tie wire.
Stainless Steel Tie Wire
Stainless steel tie wire is used with stainless rebar and in corrosive settings such as marine work, where the job specifies it.
How to Choose Rebar Tie Wire, Step by Step
- Tool or hand tying? Tool wire comes in coils made for one tool family. Hand tying uses 16 gauge wire on rolls.
- Match the wire to your tool. Check the tool model. TW1061T, TW898 and TW1525 are not interchangeable.
- Match the finish to the rebar. Black wire for black rebar, coated wire for epoxy-coated rebar, galvanized or stainless where the spec calls for it.
- Check the job spec. The drawings or the engineer may set the tie wire type and the tie pattern.
- Order enough for the pour. Count the intersections to tie and keep spare boxes on site so the crew never runs out mid-pour.
Bulk Rebar Tie Wire, On Your Schedule
Concrete contractors, rebar installers and precast plants buy rebar wire and tie wire by the box, the case and the pallet. Building the forms too? See the duplex nails in our bulk nails and our concrete pins.
Have a LINC account? Sign in to see your pricing. New customers can request a quote online or call 800.513.9918. See all our rebar tying tools and tie wire.
Get Bulk Pricing or call 800.513.9918
Rebar Tie Wire FAQs
What gauge is rebar tie wire?
16 gauge tie wire for hand tying. Tool wire is thinner, usually 19 or 21 gauge, because the tool wraps it more than once.
What tie wire does a MAX rebar tier use?
It depends on the model. The TwinTier RB441T, RB443T, RB611T and RB613T use TW1061T. The RB218, RB398/RB398S and RB518 use TW898. The RB650, RB650A and RB655 use TW1525.
Can I use regular tie wire in a rebar tying tool?
No. Tools need wire wound on the right coil for that model. Loose wire from a roll will not feed.
Do I need coated tie wire for epoxy-coated rebar?
Usually, yes. Coated tie wire keeps the tie from damaging the bar's coating, and many specs require it.
What is the difference between black and galvanized tie wire?
Black wire is plain annealed steel. Galvanized wire has a zinc coating that resists rust before the pour.
Why does rebar need to be tied?
To hold the bars in place. Rebar ties keep the mat or cage from shifting while crews walk on it and while concrete is placed and vibrated.
How often should rebar be tied?
As often as the drawings or the engineer call for. The job spec sets the tie pattern; some areas may need every intersection tied.
How much tie wire do I need for rebar?
Count the intersections you need to tie, then plan your coils or rolls from there. Keep spare boxes on site so the crew never runs out mid-pour.
Is it better to tie or weld rebar?
Tying is the standard way to hold rebar in place for the pour. Welding rebar is only done where the design calls for it.
Does rebar tie wire rust?
Plain black wire can rust before the pour. Electro galvanized tie wire resists surface rust, and stainless steel tie wire is used in corrosive settings. Once the concrete covers it, it is no longer exposed.
How do you tie rebar with tie wire by hand?
Wrap the wire around the crossed bars and twist it tight with pliers or a twister tool. A snap tie is fastest; saddle and figure-eight ties hold better where the steel will be climbed on or bumped.
Can I get volume pricing on tie wire?
Yes. Sign in to your LINC account for your pricing, or call 800.513.9918 for a quote on cases or pallets.
Another question? Call 800.513.9918 or contact us.







.jpg?width=600&height=600)